FreeStatisticalTools.com

ROC Curve and AUC: How to Interpret Them and Choose a Cut-Off

A plain-language guide to ROC curves and the area under the curve (AUC): what they show, how to interpret AUC values, how to choose the optimal cut-off with Youden's J, and how to report the results.

Free tool · runs in your browserROC Curve and AUC CalculatorFree ROC curve calculator: area under the curve with 95% CI, sensitivity, specificity and the optimal cut-off by Youden’s index.Open the tool →

A ROC curve (receiver operating characteristic curve) shows how well a continuous score separates two groups, such as patients with and without a disease, students who pass and fail, or customers who churn and stay. The AUC (area under the curve) sums that performance up in one number. ROC analysis is used to evaluate diagnostic tests, screening questionnaires, risk scores and the predicted probabilities from a logistic regression.

Key takeaways
  • The ROC curve plots sensitivity against 1 − specificity for every possible cut-off.
  • AUC = 0.5 means no better than chance; AUC = 1.0 means perfect separation.
  • Roughly: .70–.80 acceptable, .80–.90 excellent, above .90 outstanding (Hosmer and Lemeshow).
  • The cut-off with the highest Youden’s J (sensitivity + specificity − 1) balances both errors, but the best cut-off depends on the cost of each error.
In this guide
  1. Sensitivity and specificity first
  2. How to read a ROC curve
  3. What the AUC means
  4. Worked example
  5. Choosing the cut-off
  6. AUC is not the whole story
  7. How to report it in APA 7
    1. Draw a ROC curve and find the best cut-off

Sensitivity and specificity first

Any cut-off turns a continuous score into a yes/no decision (“positive if score ≥ 5”). Each decision can be right or wrong in two ways:

Truly positive Truly negative
Test positive True positive (TP) False positive (FP)
Test negative False negative (FN) True negative (TN)
  • Sensitivity = TP / (TP + FN): the share of real positives the test catches.
  • Specificity = TN / (TN + FP): the share of real negatives the test correctly clears.

Lowering the cut-off catches more positives (higher sensitivity) but also flags more negatives (lower specificity). The ROC curve shows this trade-off for every cut-off at once.

How to read a ROC curve

  • The x-axis is 1 − specificity (the false positive rate) and the y-axis is sensitivity (the true positive rate).
  • Each point on the curve is one cut-off.
  • The diagonal line is a useless test that guesses at random (AUC = 0.5).
  • The closer the curve bends towards the top-left corner, the better the test. A perfect test goes straight up to sensitivity 1 and then across.

What the AUC means

The AUC has a neat interpretation: it is the probability that a randomly chosen positive case has a higher score than a randomly chosen negative case. An AUC of .87 means that in 87% of positive–negative pairs, the positive case scores higher.

AUC Discrimination (Hosmer and Lemeshow, 2013)
0.5 None (chance)
0.5 to 0.7 Poor
0.7 to 0.8 Acceptable
0.8 to 0.9 Excellent
Above 0.9 Outstanding

An AUC below 0.5 usually means the score runs the other way (lower scores indicate the positive state). Flip the direction rather than reporting a “worse than chance” test.

Worked example

A researcher evaluates a blood biomarker for a disease in 15 patients with the disease and 15 healthy controls.

  • Disease: 9.2, 8.4, 7.9, 7.6, 7.1, 6.8, 6.6, 6.3, 6.1, 5.7, 5.4, 5.0, 4.6, 3.9, 3.2
  • Healthy: 6.4, 5.9, 5.2, 4.8, 4.5, 4.3, 4.1, 3.8, 3.6, 3.3, 3.0, 2.7, 2.5, 2.2, 1.8

The AUC is .87, 95% CI [.73, 1.00], p < .001: excellent discrimination. Here are some points on the curve:

Cut-off (positive if ≥) Sensitivity Specificity Youden’s J
6.6 .47 1.00 .47
6.1 .60 .93 .53
5.4 .73 .87 .60
5.0 .80 .80 .60
4.6 .87 .73 .60
3.9 .93 .53 .47
3.2 1.00 .33 .33

Choosing the cut-off

Youden’s J = sensitivity + specificity − 1. The cut-off with the highest J gives the best balance between the two error types. In this example three cut-offs tie at J = .60, which is common in small samples. This is where judgment comes in:

  • For a screening test, where missing a case is costly, choose the lower cut-off (4.6): it catches 87% of patients at the price of more false alarms.
  • For a confirmatory test, where false positives lead to harmful treatment, choose the higher cut-off (5.4): 87% specificity.
  • If both errors matter equally, 5.0 gives 80% on both.
Cut-offs found in your sample are optimistic

An “optimal” cut-off chosen from the same data is tuned to that sample and will usually perform a little worse on new patients. Validate it in a separate sample, or use cross-validation, before recommending it.

AUC is not the whole story

  • Prevalence matters for predictive values. Sensitivity and specificity do not depend on how common the condition is, but the positive predictive value does. A test with 90% specificity still produces many false positives when only 1% of people have the disease.
  • Compare tests on the same patients with a paired test (DeLong’s method) rather than eyeballing two AUCs.
  • Calibration is separate from discrimination. A risk model can rank people well (high AUC) but still over- or under-predict their actual risk.

How to report it in APA 7

How to report it (APA 7)
A ROC analysis evaluated how well the biomarker distinguished patients with the disease (n = 15) from healthy controls (n = 15). The biomarker showed excellent discrimination, AUC = .87, 95% CI [.73, 1.00], p < .001. A cut-off of 5.0 gave a sensitivity of 80% and a specificity of 80% (Youden's J = .60).[/fst_report] [fst_faq]
What is a good AUC value?

Above .80 is generally considered excellent and above .90 outstanding. For a screening tool, .70 to .80 can still be useful. Context matters: the same AUC can be good for predicting behaviour and poor for a medical diagnosis.


What is the difference between ROC and AUC?

The ROC curve is the graph of sensitivity against 1 − specificity across all cut-offs. The AUC is the area under that graph, a single number from 0.5 (chance) to 1 (perfect).


How do I find the optimal cut-off point on a ROC curve?

The usual method is to choose the cut-off with the largest Youden’s J (sensitivity + specificity − 1). If false negatives or false positives are more costly, choose a cut-off that favours sensitivity or specificity instead.


Can I use ROC analysis after logistic regression?

Yes. Save the predicted probabilities from the logistic regression and use them as the test score. The AUC then measures how well the model separates the two outcome groups (it equals the C statistic).


[/fst_faq]

Free tools used in this guide

Cite this article

If this guide helped your thesis, paper or class, please cite it. If you ran the analysis with one of our tools, cite the tool as well (each tool page has its own citation).

Xavier, B. (2026, November 8). ROC Curve and AUC: How to Interpret Them and Choose a Cut-Off. FreeStatisticalTools.com Blog. https://freestatisticaltools.com/blog/roc-curve-auc-interpretation/
Free eBooks · Newsletter

Get 3 free step-by-step eBooks

PLS-SEM, CB-SEM and bibliometric analysis, plus APA results templates, a thesis methods checklist and questionnaire templates. Then about two emails a month with tutorials, new tools, workshops and conferences.

  • Sent to your inbox instantly
  • Free, no spam
  • Unsubscribe anytime
See everything you get →
CB-SEM and CFA Step by Step (free eBook)PLS-SEM Step by Step (free eBook)Bibliometric Analysis Step by Step (free eBook)

Free statistics tutorials, tools, workshops and conferences

Free. About two emails a month. Unsubscribe anytime.

About Bibin Xavier

Bibin Xavier is a researcher, assistant professor, developer, digital marketer, trainer, entrepreneurship and incubation coordinator

Connect on LinkedIn →

Ask a question or leave a comment

Your email address will not be published. Required fields are marked *