FreeStatisticalTools.com

Type I and Type II Errors and Statistical Power, Explained Simply

False positives, false negatives and why underpowered studies waste effort. How alpha, beta, power, effect size and sample size fit together, with sample size examples.

Bibin Xavier3 min readSample size and power

Every hypothesis test can go wrong in two ways: it can find an effect that is not there, or miss one that is. Understanding these two errors, and statistical power, is essential for planning a study and for interpreting non-significant results.

Free tool · runs in your browserPower Analysis and Sample Size CalculatorFree a priori power analysis for t-tests, ANOVA, correlation, proportions, chi-square and regression. Required sample size and power curve, like G*Power.Calculate sample size and power →
In this guide
  1. The two errors
  2. What determines power
  3. Sample sizes for 80% power
  4. How to choose the effect size for a power analysis
  5. Interpreting a non-significant result
  6. Reporting a power analysis
  7. Frequently asked questions

The two errors

Null hypothesis true (no effect)Null hypothesis false (real effect)
Test significant (reject H₀)Type I error: false positive. Probability = αCorrect: true positive. Probability = power (1 − β)
Test not significantCorrect: true negative. Probability = 1 − αType II error: false negative. Probability = β
  • Type I error (α): concluding that a new drug works when it does not. With α = .05 you accept a 5% risk of this when there is truly no effect.
  • Type II error (β): concluding that the drug does not work when it actually does. The study missed a real effect.
  • Power (1 − β): the probability of detecting an effect that really exists. The convention is to aim for at least 80%.

What determines power

FactorEffect on power
Larger true effect sizeIncreases power
Larger sample sizeIncreases power
Less noise (reliable measures, homogeneous sample)Increases power
Higher α (.10 instead of .05)Increases power, but also more false positives
One-tailed test (in the predicted direction)Increases power
Paired or repeated measures designUsually increases power a lot

In practice, sample size is the factor researchers control most directly, which is why power analysis is mostly about choosing n.

Sample sizes for 80% power

These are the samples needed for 80% power at α = .05 (two-tailed) for medium effects, as computed by G*Power and the free power analysis calculator:

DesignMedium effectSample needed
Independent t-testd = 0.564 per group (128 total)
Paired t-testdz = 0.534 pairs
One-way ANOVA, 3 groupsf = 0.25About 159 total (53 per group)
Correlationr = .30About 84–85
Multiple regression, 5 predictorsf² = .1592

Halving the effect size roughly quadruples the sample needed. To detect a small effect (d = 0.2) with an independent t-test you need about 394 per group.

Underpowered studies are a real problem

With 30 per group and a true medium effect (d = 0.5), an independent t-test has only about 48% power, a coin flip. Underpowered studies often miss real effects, and the significant results they do find tend to overestimate the effect size.

How to choose the effect size for a power analysis

  1. Use the effect size from a meta-analysis or from similar previous studies, ideally adjusted downward because published effects are often inflated.
  2. Use the smallest effect that would matter in practice (the smallest effect size of interest). This is often the best justification.
  3. Use Cohen's benchmarks only if nothing else is available, and say so.

Interpreting a non-significant result

A non-significant result in a low-powered study is not evidence of no effect; it is simply inconclusive. Report the effect size and its confidence interval, which show which effects your data can rule out. Avoid “post hoc power” calculated from the observed effect, which adds no information beyond the p-value.

Reporting a power analysis

How to report it (APA 7)

An a priori power analysis (G*Power 3.1) indicated that 64 participants per group would provide 80% power to detect a medium effect (d = 0.50) with an independent samples t-test at α = .05 (two-tailed). To allow for 10% attrition, we recruited 71 participants per group.

Frequently asked questions

What is the difference between Type I and Type II errors?

A Type I error is a false positive: finding an effect that does not exist. A Type II error is a false negative: missing an effect that does exist.

Why is 80% power the standard?

It is a convention from Cohen, balancing the cost of larger samples against the risk of missing effects. It implies accepting a 20% chance of a Type II error, four times the usual 5% Type I risk. Some fields aim for 90%.

How can I increase power without more participants?

Use more reliable measures, a within-subjects design, a covariate such as a pretest (ANCOVA), or a more focused hypothesis. Each reduces noise relative to the effect.

What is post hoc power and should I report it?

Post hoc (observed) power is computed from the effect found in your own data. It is a direct function of the p-value and adds no information, so most methodologists advise against reporting it.

Cite the tool (APA 7)
Xavier, B. (2026). Power Analysis and Sample Size Calculator [Web application]. FreeStatisticalTools.com. https://freestatisticaltools.com/power-analysis-sample-size-calculator/

Free tools used in this guide

Cite this article

If this guide helped your thesis, paper or class, please cite it. If you ran the analysis with one of our tools, cite the tool as well (each tool page has its own citation).

Xavier, B. (2026, October 16). Type I and Type II Errors and Statistical Power, Explained Simply. FreeStatisticalTools.com Blog. https://freestatisticaltools.com/blog/type-1-type-2-errors-statistical-power/
Free eBooks · Newsletter

Get 3 free step-by-step eBooks

PLS-SEM, CB-SEM and bibliometric analysis, plus APA results templates, a thesis methods checklist and questionnaire templates. Then about two emails a month with tutorials, new tools, workshops and conferences.

  • Sent to your inbox instantly
  • Free, no spam
  • Unsubscribe anytime
See everything you get →
CB-SEM and CFA Step by Step (free eBook)PLS-SEM Step by Step (free eBook)Bibliometric Analysis Step by Step (free eBook)

Free statistics tutorials, tools, workshops and conferences

Free. About two emails a month. Unsubscribe anytime.

About Bibin Xavier

Bibin Xavier is a researcher, assistant professor, developer, digital marketer, trainer, entrepreneurship and incubation coordinator

Connect on LinkedIn →

Ask a question or leave a comment

Your email address will not be published. Required fields are marked *